File format · .v2a
TI Voyage 200 Figure Files (.fig) — Format & Repair Guide
Texas Instruments Voyage 200 figure files store geometry constructions in TI's Cabri/Journal app. Learn how these .fig files work, why they fail to open, a
The Texas Instruments Voyage 200 is a graphing calculator designed for advanced mathematics and engineering coursework. Among the many applications available for the platform is a dynamic geometry and interactive mathematics environment — derived from Cabri Geometry — that saves constructions as figure files (commonly using the .fig extension). These files let students and educators store geometric constructions, interactive diagrams, and journal-style math explorations for later use on the calculator or in TI's desktop connectivity software.
What the Format Is and What Software Uses It
The Voyage 200 is part of TI's family of advanced calculators that includes the TI-89, TI-89 Titanium, and TI-92 Plus. These devices share a common operating system and file model, and applications can be installed, archived, and transferred between calculator and computer via TI Connect or TI Graph Link software.
Figure files (.fig) are associated with geometry and interactive-graphing applications on these calculators. A .fig file typically represents a saved state of a geometry construction — points, lines, circles, transformations, measurements, and the relationships between them — or a journal entry in an interactive math exploration. When transferred to a PC, these files appear in TI Connect's file browser as application data files and can be archived, re-sent to the calculator, or organized into folders.
Related file types in the same ecosystem include:
.9?y/.v2y/.89y— variables (numbers, lists, matrices, strings, expressions).9?f/.v2f/.89f— function or program files.9?g/.v2g/.89g— grouped files bundling multiple variables.9?k/.v2k/.89k— Flash application (FlashApp) files.9?u/.v2u/.89u— operating system (OS) update images
The .fig extension specifically denotes figure/construction data rather than general-purpose variables, and it is read by the geometry application installed on the calculator rather than by the calculator's base OS directly.
Structure and Key Technical Facts
TI calculator files — whether variables, programs, applications, or figure data — are wrapped in a container format used by TI's desktop connectivity tools for transfer and storage. On the calculator itself, files are stored in the device's RAM or in Flash archive memory and managed by the TI-OS file system.
The desktop file container generally includes:
- A header identifying the file type, the target calculator model, and metadata used by TI Connect to route the file correctly when it is sent back to a device.
- A data section containing the serialized content of the figure — the geometric objects, their coordinates, their parent-child dependency relationships, display attributes (color/line style on supported devices), and any embedded calculations or measurements.
- A checksum or verification field used to confirm data integrity during transfer.
We note that Texas Instruments' official documentation is the authoritative source for exact byte-level specifications of these container formats. Community-maintained references (such as the TI file format documentation hosted on sites like ticalc.org) have reverse-engineered many of the details, but for any production repair workflow, the vendor's specifications should be treated as definitive.
Why Figure Files Become Corrupt or Unreadable
Figure files on the Voyage 200 and related calculators can become damaged or fail to open for several reasons:
- Interrupted transfers. If the USB or serial link between the calculator and computer is disconnected (or the battery dies) mid-transfer, the resulting file on either side may be truncated or carry an invalid checksum.
- Battery failure during save. If the calculator loses power while writing a figure to Flash archive, the file may be partially written, leaving the geometry application unable to parse it.
- OS or application version mismatch. A
.figfile created under one version of the geometry FlashApp may not open under a different version, or on a calculator where the application is not installed. This can look like corruption but is actually a compatibility issue. - Memory (RAM) corruption. Although rare, cosmic-ray bit flips, aging Flash memory cells, or a partial memory reset can damage the file's internal structure.
- Improper grouping or ungrouping. When figure files are bundled into a group file (
.v2g) for transfer and the ungrouping process is interrupted or fails, the extracted.figmay be incomplete. - Disk or filesystem errors on the host PC. If the file is stored on a failing hard drive, USB stick, or cloud-sync folder that experienced a sync conflict, the file on disk may be truncated or overwritten with invalid data.
What Data Can Be Recovered
In most cases, the goal of recovery is to extract the geometric construction — the points, lines, circles, measurements, and the dependency relationships that define the figure — so it can be reopened on the calculator or reconstructed in desktop geometry software.
Recoverable elements typically include:
- Object definitions — coordinates of points, equations or definitions of lines and circles, and transformation parameters.
- Dependency relationships — which objects are parents of other objects (e.g., a midpoint depends on two parent points), which is essential for the figure to remain interactive rather than just a static drawing.
- Measurements and calculations — any embedded numeric readouts (lengths, angles, areas) and their formulas.
- Display attributes — line styles, labels, and visibility flags.
If the file is too badly damaged to restore fully, partial recovery may still yield the raw object list, which can be used to manually rebuild the construction.
How Recovery Works
Recovery of a Voyage 200 figure file generally follows this process:
-
Diagnostic inspection. The file is examined to determine whether the damage is in the TI Connect container header, the data payload, or the checksum. A file that fails to open in TI Connect but has an intact data section is often recoverable.
-
Container repair. If the header or checksum is invalid (a common result of interrupted transfer), the header can sometimes be rebuilt using known-good values from a valid file of the same type, and the checksum recalculated to match the actual data.
-
Data extraction. The serialized geometry data is parsed directly, bypassing the damaged container. Community-developed tools and documentation of the TI variable file format can guide this step, extracting the object list and dependency tree.
-
Reconstruction. Once the object data is recovered, the figure can be reassembled into a valid
.figfile or imported into compatible desktop geometry software for verification and re-transfer to the calculator. -
Verification. The recovered file is tested — ideally on both TI Connect and an actual Voyage 200 (or TI-89 / TI-92 Plus with the same geometry application) — to confirm that the construction opens and that interactive relationships are intact.
Frequently Asked Questions
What is a .fig file on the TI Voyage 200?
It is a figure file created by the calculator's geometry or interactive mathematics application, storing a geometric construction — points, lines, shapes, measurements, and the relationships between them — so it can be reopened and manipulated later.
Can I open a Voyage 200 .fig file on my computer?
TI Connect and TI Graph Link can manage .fig files (transfer, archive, and organize them), but to actually view or interact with the construction you typically need the geometry application running on a compatible calculator or an equivalent desktop environment. TI Connect itself does not render the figure visually.
My .fig file won't transfer to the calculator. Is it corrupt?
Not necessarily. The most common cause is that the geometry FlashApp is not installed on the target calculator, or the OS or application version does not match. Check that the correct application is installed and that the file was created for the same calculator family.
Can a .fig file from a TI-89 or TI-92 Plus be used on the Voyage 200?
In many cases yes, because these calculators share the same core OS and application architecture. However, version differences in the geometry application can cause compatibility issues. When in doubt, verify the application version on both devices.
Is it possible to recover a figure file after a battery failure during save?
Often, yes. If the Flash archive write was interrupted, the file may be partially written or carry an invalid checksum. A repair tool that can parse the TI container format and reconstruct the header/checksum may be able to recover the underlying geometry data.
If you have a damaged Voyage 200 figure file — or any TI calculator file that will not open or transfer correctly — send it to our team for a free evaluation. We will inspect the file, determine what can be recovered, and provide a clear assessment with no obligation.
Send us your .v2a file for a free evaluation
Our recovery engineers will tell you exactly what can be recovered — at no cost. There is no charge if we cannot recover your data.
Start a free evaluation